94 research outputs found

    Spiral cracks in drying precipitates

    Full text link
    We investigate the formation of spiral crack patterns during the desiccation of thin layers of precipitates in contact with a substrate. This symmetry-breaking fracturing mode is found to arise naturally not from torsion forces, but from a propagating stress front induced by the fold-up of the fragments. We model their formation mechanism using a coarse-grain model for fragmentation and successfully reproduce the spiral cracks. Fittings of experimental and simulation data show that the spirals are logarithmic, corresponding to constant deviation from a circular crack path. Theoretical aspects of the logarithmic spirals are discussed. In particular we show that this occurs generally when the crack speed is proportional to the propagating speed of stress front.Comment: 4 pages, 5 figures, RevTe

    Anterior-inferior plating of middle-third fractures of the clavicle

    Get PDF
    © The Author(s) 2009. This article is published with open access at Springerlink.com Introduction Various techniques have been reported for the treatment of middle-third clavicle (collar bone) fractures. This prospective study was conducted to evaluate the results of anterior-inferior plating using a 3.5-mm reconstruction plate for the treatment of middle-third clavicle fractures

    Outcome analysis following removal of locking plate fixation of the proximal humerus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Concerning surgical management experience with locking plates for proximal humeral fractures has been described with promising results. Though, distinct hardware related complaints after fracture union are reported. Information concerning the outcome after removal of hardware from the proximal humerus is lacking and most studies on hardware removal are focused on the lower extremity. Therefore the aim of this study was to analyze the functional short-term outcome following removal of locking plate fixation of the proximal humerus.</p> <p>Methods</p> <p>Patients undergoing removal of a locking plate of the proximal humerus were prospectively followed. Patients were subdivided into the following groups: Group HI: symptoms of hardware related subacromial impingement, Group RD: persisting rotation deficit, Group RQ: patients with request for a hardware removal. The clinical (Constant-Murley score) and radiologic (AP and axial view) follow-up took place three and six months after the operation. To evaluate subjective results, the Medical Outcomes Study Short Form-36 (SF-36), was completed.</p> <p>Results</p> <p>59 patients were included. The mean length of time with the hardware in place was 15.2 ± 3.81 months. The mean of the adjusted overall Constant score before hardware removal was 66.2 ± 25.2% and increased significantly to 73.1 ± 22.5% after 3 months; and to 84.3 ± 20.6% after 6 months (p < 0.001). The mean of preoperative pain on the VAS-scale before hardware removal was 5.2 ± 2.9, after 6 months pain in all groups decreased significantly (p < 0.001). The SF-36 physical component score revealed a significant overall improvement in both genders (p < 0.001) at six months.</p> <p>Conclusion</p> <p>A significant improvement of clinical outcome following removal was found. However, a general recommendation for hardware removal is not justified, as the risk of an anew surgical and anesthetic procedure with all possible complications has to be carefully taken into account. However, for patients with distinct symptoms it might be justified.</p

    Application of layered poly (L-lactic acid) cell free scaffold in a rabbit rotator cuff defect model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study evaluated the application of a layered cell free poly (L-lactic acid) (PLLA) scaffold to regenerate an infraspinatus tendon defect in a rabbit model. We hypothesized that PLLA scaffold without cultivated cells would lead to regeneration of tissue with mechanical properties similar to reattached infraspinatus without tendon defects.</p> <p>Methods</p> <p>Layered PLLA fabric with a smooth surface on one side and a pile-finished surface on the other side was used. Novel form of layered PLLA scaffold was created by superimposing 2 PLLA fabrics. Defects of the infraspinatus tendon were created in 32 rabbits and the PLLA scaffolds were transplanted, four rabbits were used as normal control. Contralateral infraspinatus tendons were reattached to humeral head without scaffold implantation. Histological and mechanical evaluations were performed at 4, 8, and 16 weeks after operation.</p> <p>Results</p> <p>At 4 weeks postoperatively, cell migration was observed in the interstice of the PLLA fibers. Regenerated tissue was directly connected to the bone composed mainly of type III collagen, at 16 weeks postoperatively. The ultimate failure load increased in a time-dependent manner and no statistical difference was seen between normal infraspinatus tendon and scaffold group at 8 and 16 weeks postoperatively. There were no differences between scaffold group and reattach group at each time of point. The stiffness did not improve significantly in both groups.</p> <p>Conclusions</p> <p>A novel form of layered PLLA scaffold has the potential to induce cell migration into the scaffold and to bridge the tendon defect with mechanical properties similar to reattached infraspinatus tendon model.</p